Vertical LAr Storage Tank

BluNet vertical LAr storage tanks are designed for reliable bulk storage of liquid argon in industrial gas supply systems.
Available in capacities from 5 m³ to 100 m³, with working pressure options of 0.8 MPa and 1.6 MPa.
The tanks feature a stainless steel inner vessel, carbon steel outer vessel, and vacuum-perlite insulation.
Multiple configurations are available to meet different storage capacities and installation requirements.
Suitable for industrial gas supply facilities and applications requiring a dependable liquid argon reserve.

BluNet manufactures **vertical LAr cryogenic storage tanks** for the stationary storage of liquid argon at cryogenic temperatures. These tanks are designed for industrial gas supply systems that require on-site liquid argon storage for downstream vaporization or liquid transfer.

BluNet’s LAr cryogenic tank range serves industrial gas facilities, metal processing operations, laboratories, and other applications requiring a reliable liquid argon supply. Tank selection can be tailored to storage demand, site conditions, operating requirements, and applicable design standards.

High-quality liquid argon tank for industrial and laboratory cryogenic storage
BluNet Liquid Argon Tank engineered for safe, efficient, and ultra-pure cryogenic storage

Key Features

  • Capacity options: Nominal storage capacities of 5, 10, 15, 20, 30, 50, and 100 m³.
  • Working pressure options: 0.8 MPa and 1.6 MPa, depending on the selected model.
  • Vacuum-perlite insulation: The insulated annular space helps minimize heat ingress and reduce liquid argon evaporation.
  • Stainless steel inner vessel: 06Cr19Ni10 stainless steel is specified for the inner tank.
  • Carbon steel outer vessel: Q235-B carbon steel is specified for the outer tank.
  • Vertical configuration: The upright design supports stationary bulk storage where the available installation footprint is limited.
  • Multiple capacity and pressure combinations: Customers can compare tank capacity, working pressure, weight, and dimensions to identify a suitable configuration.

Technical Specifications of Vertical LAr Cryogenic Storage Tanks

The following table summarizes the supplied specifications for the vertical tank series. Static evaporation rates are shown specifically for liquid argon (LAr). Actual performance depends on the tank design, operating conditions, and measurement basis.

Model Nominal Capacity (m³) Working Pressure (MPa) Static Evaporation Rate (%/day) Inner Vessel Weight (kg) Total Weight (kg)
DSWV-5/0.8 5 0.8 0.46 1,040 4,430
DSWV-5/1.6 5 1.6 0.46 1,600 5,050
DSWV-10/0.8 10 0.8 0.38 1,980 7,230
DSWV-10/1.6 10 1.6 0.38 3,020 8,260
DSWV-15/0.8 15 0.8 0.37 2,735 9,080
DSWV-15/1.6 15 1.6 0.37 4,460 10,910
DSWV-20/0.8 20 0.8 0.35 3,575 11,010
DSWV-20/1.6 20 1.6 0.35 5,530 12,965
DSWV-30/0.8 30 0.8 0.31 5,300 16,440
DSWV-30/1.6 30 1.6 0.31 8,300 19,510
DSWV-50/0.8 50 0.8 0.24 8,705 25,870
DSWV-50/1.6 50 1.6 0.24 14,045 31,210
DSWV-100/0.8 100 0.8 0.17 16,140 48,765
DSWV-100/1.6 100 1.6 0.17 27,570 60,200

Note: Static evaporation rates are manufacturer-supplied reference values. Confirm the test conditions and whether the values represent guaranteed performance before using them as contractual specifications. Weights are subject to confirmation against the final approved design.

Vertical LAr Tank Dimensions

The following dimensions are based on the supplied tank data. Dimensions are expressed as diameter × length × nominal wall thickness, in millimeters. Inner-vessel wall thickness varies by working pressure and model, so refer to the model-specific entries below when planning installation or requesting a quotation.

Model Inner Vessel Dimensions (mm) Outer Vessel Dimensions (mm)
DSWV-5/0.8 Ø1400 × 3680 × 6 Ø1900 × 5115 × 8
DSWV-5/1.6 Ø1400 × 3680 × 10 Ø1900 × 5115 × 8
DSWV-10/0.8 Ø1700 × 4950 × 8 Ø2200 × 6400 × 8
DSWV-10/1.6 Ø1700 × 4950 × 12 Ø2200 × 6400 × 8
DSWV-15/0.8 Ø1900 × 5950 × 8 Ø2400 × 7330 × 8
DSWV-15/1.6 Ø1900 × 5950 × 14 Ø2400 × 7330 × 8
DSWV-20/0.8 Ø2100 × 6465 × 8/10 Ø2600 × 7955 × 8
DSWV-20/1.6 Ø2100 × 6465 × 14 Ø2600 × 7955 × 8
DSWV-30/0.8 Ø2400 × 7410 × 10 Ø3000 × 8930 × 10
DSWV-30/1.6 Ø2400 × 7410 × 16 Ø3000 × 8930 × 10
DSWV-50/0.8 Ø2600 × 10380 × 10/12 Ø3200 × 12000 × 12
DSWV-50/1.6 Ø2600 × 10380 × 18/20 Ø3200 × 12000 × 12
DSWV-100/0.8 Ø3000 × 15425 × 12/14 Ø3600 × 17260 × 14*
DSWV-100/1.6 Ø3000 × 15425 × 22 Ø3600 × 17260 × 14*

Dimension Note: Verify the 100 m³ outer-vessel dimensions against the manufacturer’s approved drawing before publication or installation planning. Confirm whether slash-separated wall thicknesses apply to different vessel sections.

How Vacuum-Perlite Insulation Works

Liquid argon must be maintained at cryogenic temperatures to remain in liquid form. Heat entering the storage vessel can cause part of the liquid to vaporize, increasing pressure and resulting in product loss or the need to manage boil-off gas.

A vacuum-perlite insulation system helps limit this heat transfer. The space between the inner and outer vessels is filled with expanded perlite and evacuated to reduce heat transfer through the insulating layer. The combination of the vacuum and insulating material helps maintain storage conditions and supports a lower static evaporation rate.

Actual evaporation performance depends on the tank’s insulation design, ambient conditions, operating pressure, liquid fill level, and the method used to measure the rate. Buyers should review the manufacturer’s specified test basis when comparing different tank models.

Applications

Vertical LAr cryogenic storage tanks are used where liquid argon is delivered in bulk and stored before being transferred to downstream equipment or converted into gaseous argon by a suitable vaporizer.

Typical applications include:

  • Metal fabrication and welding: Supplying argon for shielding and other industrial welding processes.
  • Metallurgy and metal processing: Providing argon for selected inert-atmosphere and process applications.
  • Electronics and advanced manufacturing: Supporting processes that require a controlled argon supply.
  • Laboratories and research facilities: Storing liquid argon for suitable scientific and technical applications.
  • Industrial gas distribution: Serving as bulk storage in liquid argon supply installations.

The final installation should include appropriately selected transfer piping, valves, pressure-control and relief devices, instrumentation, and vaporization equipment where required. These components must be designed for the intended service and applicable regulations.

How to Select the Right Vertical LAr Storage Tank

Choosing a suitable liquid argon tank requires more than matching the nominal capacity to daily consumption. Buyers should consider the following factors:

  • Liquid argon demand: Estimate average and peak consumption, delivery frequency, and the required reserve capacity.
  • Working pressure: Select the 0.8 MPa or 1.6 MPa option based on the system’s operating requirements and the approved design.
  • Installation space: Check vessel dimensions, overall height, foundation requirements, transport access, and maintenance clearance.
  • Downstream supply: Confirm the required gas flow, delivery pressure, and whether a vaporizer and pressure-regulating system are needed.
  • Applicable standards: Specify the required design code, inspection, certification, and local regulatory requirements before ordering.

For broader equipment options, visit BluNet’s LAr Cryogenic Tank category or learn more about BluNet’s cryogenic tank manufacturing capabilities.

Vertical LAr Tank vs. Horizontal LAr Tank

A vertical tank is often considered when ground space is limited and sufficient installation height is available. A horizontal tank may be more appropriate where overhead clearance is restricted or the site layout favors a low-profile vessel. The final choice depends on capacity, engineering design, foundation conditions and operating requirements.

TECHNICAL FAQs

FAQ About Vertical LAr Storage Tanks

What sizes are available for vertical liquid argon storage tanks?

BluNet offers vertical liquid argon (LAr) cryogenic storage tanks with capacities ranging from 5 m³ to 100 m³. Available sizes include 5, 10, 15, 20, 30, 50, and 100 m³. The right capacity depends on your argon consumption, delivery schedule, and required storage reserve.

What working pressure should I choose for a vertical LAr tank?

The available tank configurations have working pressures of 0.8 MPa or 1.6 MPa. Your choice should depend on the operating pressure required by your liquid argon storage and supply system, as well as the applicable design requirements.

How does the tank keep liquid argon cold?

The tank uses vacuum-perlite insulation to reduce heat transfer from the surrounding environment. This helps maintain cryogenic storage conditions and limit liquid argon evaporation. Actual evaporation rates depend on the tank design and the specified test conditions.

What materials are used in BluNet's vertical LAr storage tanks?

The supplied specifications list 06Cr19Ni10 stainless steel for the inner vessel and Q235-B carbon steel for the outer vessel. The final material specifications should be confirmed for the selected model and project requirements.

How do I choose the right liquid argon storage tank for my facility?

Start by considering your daily argon consumption, delivery frequency, required storage capacity, operating pressure, and available installation space. You should also assess downstream vaporization and gas supply requirements. Contact BluNet with your project details for help selecting a suitable configuration and requesting a quotation.

Reviews

There are no reviews yet.

Be the first to review “Vertical LAr Storage Tank”

Reviews

There are no reviews yet.

Be the first to review “Vertical LAr Storage Tank”